Leave Your Message

TSFLCGEWOEU Medium voltage flat reeling cable

The Medium voltage flat reeling cable as power supply with reinforced PUR sheath is very suitable for high and extreme mechanical stress used wherever cable operation requires frequent reeling and unreeling on pulleys, drums or rollers indoors or outdoors in wet or dry conditions. Such as Ship to Shore Cranes, Rail Mounted Gantry Cranes and other heavy mobile equipment

    nullConstruction

    Conductor: Extra fine bare copper conductor class 6 VDE 0295

    Insulation: Special rubber compound based on NBR

    Reinforce: Protective earth conductor Individually braid of tinned copper wires

    Core: Fiber optics / control cores

    Advantages: Outer sheath PUR resistant to tearing, notching and abrasion

    Technical Date​

    Specification(mm2)

    Overall diameter(mm)

    Approx weight(kg/m)

    Tensile  Load(N)

    Current at 30℃(A)

    Max. resistance of the Current at 30℃(Ω/KW)

    Voltagedrop per 100m(V)

    3*35+1*16+12FO

    69.2*15.9

    2.210

    2057

    155

    0.576

    17.86

    3*50+1*25+12FO

    82.7*18.5

    3.111 

    2973 

    175 

    0.401

    14.04 

    3*70+1*35+12FO

    92.6*20.6

    4.053 

    4165 

    220 

    0.283

    12.45 

    3*95+1*50+12FO

    108*22.7

    5.349 

    5695 

    260 

    0.214

    11.13 

    3*120+1*70+12FO

    121.7*26.9

    7.015 

    7310 

    320 

    0.167

    10.69 

    3*150+1*70+12FO

    130.9*29

    8.342 

    8842 

    385 

    0.134

    10.32 

    3*185+1*95+12FO

    149.4*32.3

    10.476 

    11049 

    430 

    0.11

    9.46 

    3*240+1*120+12FO

    164.7*37.3

    13.460 

    14281 

    535 

    0.0833

    8.91 

    3*35+2*16+12FO

    80.5*16

    2.547 

    2329 

    155 

    0.576

    17.86 

    3*50+2*25+12FO

    94*18.5

    3.547 

    3398 

    175 

    0.401

    14.04 

    3*70+2*35+12FO

    104.8*20.6

    4.610 

    4760 

    220 

    0.283

    12.45 

    3*95+2*50+12FO

    121.9*22.7

    6.087 

    6544 

    260 

    0.214

    11.13 

    3*120+2*70+12FO

    134.8*26.9

    7.933 

    8500 

    320 

    0.167

    10.69 

    3*150+2*70+12FO

    142.9*29

    9.254 

    10032 

    385 

    0.134

    10.32 

    3*185+2*95+12FO

    162.8*32.3

    11.667 

    12664 

    430 

    0.11

    9.46 

    3*240+2*120+12FO

    177.5*37.3

    14.876 

    16321 

    535 

    0.0833

    8.91 

    Specification(mm2)

    Overall diameter(mm)

    Approx weight(kg/m)

    Tensile  Load(N)

    Current at 30℃(A)

    Max. resistance of the Current at 30℃(Ω/KW)

    Voltagedrop per 100m(V)

    3*35+12*2.5+12FO

    88*16

    2.579

    2294

    155

    0.576

    17.86

    3*50+12*2.5+12FO

    97*18.5

    3.362 

    3058 

    175 

    0.401

    14.04 

    3*70+12*2.5+12FO

    93.3*20.6

    3.909 

    4079 

    220 

    0.283

    12.45 

    3*95+12*2.5+12FO

    102.5*22.7

    4.914 

    5354 

    260 

    0.214

    11.13 

    3*120+12*2.5+12FO

    112.9*26.9

    6.299 

    6629 

    320 

    0.167

    10.69 

    3*150+16*2.5+12FO

    123.4*29

    7.695 

    8161 

    385 

    0.134

    10.32 

    3*185+19*2.5+12FO

    140.2*32.3

    9.540 

    9943 

    430 

    0.11

    9.46 

    3*240+24*2.5+12FO

    153.3*37.3

    12.284 

    12750 

    535 

    0.0833

    8.91 

    Technical Info

    Working voltage: 3.6/6KV

    Test Voltage: 12.5 kV AC (5 Min.)

    Working temperature: Fixed:-50-125℃ Remove: -30-125℃

    Bending radius: Fixed: 6*thickness of cableFlexing: 10* thickness of cable